Tinospora cordifolia Extract Achieves 87 Percent Biocorrosion Inhibition on
A natural stem extract from the medicinal plant Tinospora cordifolia has demonstrated significant biocide and corrosion-inhibition efficacy against mild steel degradation driven by Pseudomonas aeruginosa in a simulated seawater environment. In laboratory evalu
Illustrative imageA natural stem extract from the medicinal plant Tinospora cordifolia has demonstrated significant biocide and corrosion-inhibition efficacy against mild steel degradation driven by Pseudomonas aeruginosa in a simulated seawater environment. In laboratory evaluations conducted across controlled immersion trials, the botanical formulation achieved an optimum corrosion inhibition efficiency of 87.58 percent when applied at a concentration of 300 milligrams per liter. Mild steel test specimens exposed to aggressive marine-simulated conditions without protection suffered rapid degradation, whereas the introduction of the plant-derived biocide markedly suppressed both microbial activity and metallic dissolution. Electrochemical measurements and surface microscopic examinations confirmed that the extract concurrently hindered the establishment of bacterial biofilms and formed a protective barrier layer directly across the steel substrate. These findings demonstrate that plant-based phytochemical treatments can provide dual-action defense against microbially influenced corrosion, offering an environmentally benign alternative to persistent chemical treatments in marine and industrial infrastructure where bacterial colonization and accelerated surface deterioration frequently occur simultaneously.
The ubiquitous marine bacterium Pseudomonas aeruginosa plays a prominent role in accelerating localized and general structural deterioration through the production of dense, sticky biofilms composed of extracellular polymeric substances. When bacteria adhere to metal surfaces, this heterogeneous extracellular matrix establishes localized gradients in oxygen concentration, generating distinct electrochemical cells where areas beneath the biofilm turn anodic while adjacent exposed regions become cathodic. In the baseline control experiments of the investigation, mild steel coupons immersed in sterile simulated seawater exhibited a baseline corrosion rate of 14.63 mils per year. When Pseudomonas aeruginosa cultures were introduced into the simulated marine electrolyte without inhibitor, the corrosion rate rose substantially to 16.64 mils per year, validating the bacterium’s capacity to accelerate metallic dissolution.
Industrial mitigation of microbially induced corrosion has historically depended on synthetic chemical biocides such as glutaraldehyde, quaternary ammonium compounds, and isothiazolinone formulations, which generally demonstrate microbial inhibition efficiencies ranging between 70 percent and 95 percent. Furthermore, numerous conventional green corrosion inhibitors can passivate metal surfaces but lack substantive antimicrobial efficacy, leaving structural components vulnerable to persistent bacterial colonization in microbially active environments. While previous investigations evaluated crude extracts from botanical sources including Uncaria laevigata, Syzygium aromaticum, Ceratonia siliqua, Glycyrrhiza glabra, Citrus reticulata peels, and garlic oil, many suffered from comparatively low protective efficiency. The dual-function capacity of Tinospora cordifolia extract, which simultaneously suppresses bacterial proliferation and passivates steel surfaces, provides a competitive advantage for sustainable marine engineering management.
To prepare the experimental botanical formulation, Tinospora cordifolia vegetative specimens were obtained from regional markets and formally authenticated at the Herbarium Bogoriense laboratory located in Cibinong. The harvested plant stems were systematically dried, pulverized into small fragments, and subjected to a solid-liquid maceration extraction process at room temperature using a blended methanol and water solvent mixture. Following extraction, the resulting liquid fraction was concentrated under reduced pressure utilizing a low-pressure vacuum evaporator and preserved under controlled conditions. Simultaneously, pure cultures of Pseudomonas aeruginosa strain ATCC 15442 were sourced from the Department of Biology at IPB University. The microbial strain was initially transferred into freshwater culture before being inoculated into nutrient broth and an artificial seawater medium. To expand the active bacterial population for experimental inoculation, the microorganisms were subcultured into larger volumes of seawater media and incubated at 37 degrees Celsius for 24 hours prior to metallic exposure testing.
Biofilm inhibition and electrochemical corrosion trials were performed using mild steel coupons immersed in 200 milliliters of bacterial medium contained within 250-milliliter Erlenmeyer flasks. The test coupons were exposed to Pseudomonas aeruginosa inoculants at room temperature for 24 hours in the presence or absence of varying inhibitor concentrations. Following this exposure period, the coupons were transferred into an electrochemical cylindrical testing cell coupled to a Gamry PCI4G750 potentiostat outfitted with a standard three-electrode configuration. This arrangement utilized a platinum counter electrode, a saturated calomel reference electrode, and the treated mild steel specimen as the working electrode. Open circuit potential scans were recorded over 600 seconds with an acquisition period of 0.5 seconds to monitor potential stabilization. Potentiodynamic polarization tests were subsequently performed across a potential window of plus or minus 250 millivolts relative to the open circuit potential at a scan rate of one millivolt per second.
Potentiodynamic polarization curves revealed distinct shifts in electrochemical behavior upon the introduction of Tinospora cordifolia extract to the inoculated seawater electrolyte. The corrosion potential shifted toward more negative values across the polarization curves, indicating enhanced surface passivation and corrosion mitigation compared to uninhibited baseline specimens. Concurrently, the corrosion current density decreased substantially with increasing extract concentrations, reflecting a direct deceleration of metallic dissolution reactions. Analysis of the electrochemical parameters demonstrated that the displacement in corrosion potential relative to the uninhibited condition remained below 85 millivolts across all concentrations. According to electrochemical classification principles, inhibitor compounds exhibiting potential shifts below this threshold function as mixed-type inhibitors, confirming that the phytochemical constituents suppress both anodic metal dissolution and cathodic reduction reactions. The optimum performance occurred at an extract concentration of 300 milligrams per liter, reducing current density to yield a maximum corrosion inhibition efficiency of 87.58 percent.
Electrochemical impedance spectroscopy conducted over a broad frequency spectrum spanning from 0.1 hertz to 50,000 kilohertz provided quantitative evidence regarding interface charge dynamics and film resistance. Nyquist plots recorded in the presence of the botanical biocide exhibited characteristic depressed semicircular arcs in high-frequency regions, a signature of semiconducting passive film development on the mild steel surface. As extract concentrations were elevated, the semicircular arc diameters enlarged considerably, demonstrating an increase in charge transfer resistance across the metal-solution interface. Bode plot spectra showed a corresponding increase in total impedance magnitude across all tested frequencies, validating heightened surface protection against corrosive electrolyte ingress. Furthermore, phase angle profiles exhibited systematic shifts at low frequencies, reflecting altered reaction kinetics and film accumulation, reaching a maximum phase angle peak of approximately negative 72 degrees in electrolytes treated with the optimal 300 milligram per liter extract concentration.
To evaluate the interfacial adsorption mechanism governing the protective action of Tinospora cordifolia constituents on mild steel, empirical data were fitted to the Langmuir adsorption isotherm model relating extract concentration to surface coverage. The resulting linear plot of concentration divided by surface coverage against concentration yielded a correlation coefficient of 0.9095 and a slope of 1.122, demonstrating reasonable adherence to monolayer adsorption behavior. The slight departure from ideal Langmuir behavior was attributed to metal surface heterogeneity and competitive adsorption among multiple organic molecules within the crude extract. Thermodynamic calculations derived from the adsorption equilibrium constant of 2.83 times 10 to the negative second power milligrams per liter yielded a standard free energy of adsorption of negative 25.39 kilojoules per mole at 303 Kelvin. Because free energy values between negative 20 and negative 40 kilojoules per mole represent combined physical and chemical interactions, the adsorption process operated via spontaneous physis-chemisorption involving both electrostatic attraction and chemical coordination.
Liquid chromatography-tandem mass spectrometry characterization of the Tinospora cordifolia extract resolved dominant bioactive phytochemical constituents, identifying the bioactive alkaloid derivative moupinamide as a central agent contributing to antimicrobial and protective efficacy. Structurally, moupinamide incorporates amide and methoxy functional groups anchored to an aromatic ring system, providing nitrogen and oxygen heteroatoms bearing unshared electron pairs. In corrosive aqueous environments, mild steel exposes iron ionic species with accessible 3d electron orbitals that accept lone pair donations from these heteroatoms, establishing coordinative covalent linkages directly at the metallic interface. Complementary pi-orbital interactions across the planar aromatic framework facilitate extensive surface coverage, forming a robust chemisorbed barrier layer that blocks active dissolution sites. Simultaneously, the antimicrobial action of the compound disrupts bacterial cell membrane integrity and metabolic pathways necessary for biofilm proliferation, as corroborated by field-emission scanning electron microscopy displaying smooth, intact coupon surfaces compared to the heavily corroded, biofilm-encrusted surfaces observed without extract.
Despite the promising laboratory efficacy demonstrated by Tinospora cordifolia extract, researchers emphasized that practical deployment in real-world marine systems requires addressing several experimental limitations. Furthermore, natural botanical compounds can undergo rapid environmental degradation, necessitating thorough evaluations of formulation longevity, shelf-life stability, repeated-dose requirements, and controlled-release delivery technologies. Future research must also evaluate comprehensive ecotoxicological impacts on non-target marine species and surrounding ecosystems to verify benign environmental profiles. Quantitative biomass assays tracking live and dead cell ratios, along with field-scale pilot validations on operational marine structures, will be essential steps to transition this botanical extract from controlled laboratory experimentation into a reliable, sustainable commercial biocide for marine engineering infrastructure.
Subject of Research: Botanical biocide inhibition of microbially influenced mild steel corrosion in simulated seawater
Article Title: The biocide potential of Tinospora cordifolia extract against biocorrosion caused by Pseudomonas aeruginosa in a seawater-simulated environment
Article References: Royani, A., Dewi Narrij Lotulung, P., Lestari, Y., Musabikha, S., Nikitasari, A., Kusumastuti, R., Priyotomo, G., Hanafi, M., & Manaf, A. (2026). The biocide potential of Tinospora cordifolia extract against biocorrosion caused by Pseudomonas aeruginosa in a seawater-simulated environment. Surface Science and Technology, 4(1), Article 37. https://doi.org/10.1007/s44251-026-00143-7
Image Credits: AI Generated
DOI: 10.1007/s44251-026-00143-7
Keywords: Tinospora cordifolia, Pseudomonas aeruginosa, biocorrosion, mild steel, simulated seawater, biofilm inhibition, electrochemical impedance spectroscopy, potentiodynamic polarization, open circuit potential, moupinamide, green biocide, physis-chemisorption, Langmuir adsorption isotherm, corrosion rate, surface passivation, marine microbiology, charge transfer resistance, microbially influenced corrosion
News Source: Denise Maddox. (November 26, 2026). Tinospora cordifolia Extract Achieves 87 Percent Biocorrosion Inhibition on Mild Steel. Scienmag.